Introduction
-Bacstain - series offer several kinds of bacterial fluorescence staining dye and can be applied for microbial cell viability
assay in different principles.
CTC has been used by many researchers to evaluate the microbial respiratory activity.
-Bacstain - CTC Rapid Staining Kits allows quick and high-sensitivity CTC-staining.
Kit contents
CTC (5-cyano-2,3-ditolyl tetrazolium chloride) | 10 mg x 3 |
Enhancing reagent A | 100 μl (DMSO solution) x 1 |
Storage
Store at 0-5ºC
Required Equipment
- Incubator
- Micropipette (20 μl, 1,000 μl)
- Flow cytometer (488 nm laser, red emission filter)
Staining procedure
- 1. Add 750 μl of distilled water to one CTC tube and vortex gently to dissolve (final concentration 50 mmol/l) a) .
- Resuspend the organism with PBS(-) or saline and adjust the number of cells to 106 cells/ml (flow cytometry) b) .
- Add each reagent into the 1 ml of microbial cell suspension and vortex gently to mix.
Refer to the conditions in the following tables.CTC solution Enhancing reagent A Enhancing reagent A 20 μl 1 μl - Incubate the microbial cells at 37 ℃ for 30 minc).
- Analyze the stained cells by flow cytometer or under a microscope.
a) | This solution is stable at -20°C for 2 weeks. |
b) | Since remaining culture medium in the sample undergoes unspecific colored-reaction, it should be duly removed. |
c) | When CTC-staining is insufficient, add extra CTC solution or increase the incubation time. In this case, CTC solution should be limited less or equal to 100 μl/sample. |
CTC staining efficiencies were compared in with or without enhancing reagent condition.
-
Right-image : without enhancing reagent
Left-image : with enhancing reagentEx filter : Blue
Em filter: Red
Enhancer (+)
-
Upper figures : with enhancing reagent
Lower figures : without enhancing reagent
Enhancer (-)
-
X-axis:
Fluorescence intensity of CTC-formazan
CTC staining of Candida albicans in flow cytometry
Counterstaining (Optional)
-Bacstain- DAPI solution is utilized for the nucleotide staining of bacteria either with membrane impairment or with intact membrane. Since CTC only stains viable aerobic cells, double staining using CTC and DAPI enable to identify viable aerobic cells among the entire cell population. Formaldehyde fixation (1–4% final concentration) is not required for the DAPI staining. However, if fixation is necessary for the downstream experiment or if the formaldehyde fixation is a standard protocol to prepare samples, it can be done in between CTC staining and DAPI staining. In this case, please add 1 μl of DAPI solution to CTC-stained cell suspension (approx. 1 ml) and then incubate the sample at room temperature for 5 min.
Number of Tests possible
This kit can perform at least 100 tests for the flow cytometric assay and the microscopic assay by following the protocol described herein.
References
- A.Hiraishi and N.Yoshida, "An Improved Redox Dye-Staining Method Using 5-Cyano-2, 3-Ditoryl Tetrazolium Chloride
for Detection of Metabolically Active Bacteria in Activated Sludge", Microbes Environ. , 2004, 19 (1), 61. - A. Kitaguchi, N. Yamaguchi and M. Nasu, "Enumeration of Respiring Pseudomonas spp. in Milk within 6 Hours by
Fluorescence In Situ Hybridization Following Formazan Reduction", Appl. Environ. Microbiol ., 2005, 71 (5), 2748.
Relevant products
-Bacstain - CFDA solution
CFDA is widely used as an indicator for the measurement of esterase activity.
-Bacstain- CFDA solution is provided as Ready-to-Use DMSO solution.
Fluorescent carboxyfluorescein is produced from non fluorescent CFDA by the esterase in the microbial cell.
-
Double-staining of S.epidermidis (CFDA/EB)
X-axis : Fluorescence intensity of CFDA
Y-axis : Fluorescence intensity of PI
-Bacstain - DAPI solution, AO solution
DAPI and AO are nucleic acid staining dyes and can be applied for bacteria either with membrane impairment or with
intact membrane.
-Bacstain - PI solution
PI is a nucleic acid staining dye. Membrane-injured cells are stained with red emission by PI.
-
Double-staining of S.epidermidis (DAPI/PI)
Red fluorescence represents membrane-injured cells
Products | Code | Maximum Ex/Em(nm) | Number of assays |
CTC Rapid Staining Kit (for Flow cytometry) | BS01 | 430, 480/630 | 100 |
CTC Rapid Staining Kit (for Microscopy) | BS02 | 430, 480/630 | 100 |
CFDA solution | BS03 | 493/515 | 100 |
DAPI solution | BS04 | 360/460 | 100 |
AO solution | BS05 | 420-460/630-650(ssDNA) 500/520(dsDNA) |
100 |
PI solution | BS07 | 530/620 | 100 |
These products were developed by joint-research with Fukuoka Industrial Technical Center in Japan.
Frequently Asked Questions / Reference
BS01: -Bacstain- CTC Rapid Staining Kit (for Flow cytometry)
Revised Aug., 28, 2023