Glucose Assay Kit-WST

$180.00$390.00

∼ Features ∼
Used to determine intracellular levels of Glucose.

Storage Condition: Store: at 0-5oC
Shipping Condition:  ambient temperature

Kit Contents:

Clear


Mix and match products can be applied.
You must enter coupon code on your order to receive the discount!
・Summer 21-2 (for buying 2)
・Summer 21-3 (for buying 3 and more)
(Can not be combined with any other offer or special pricing products.)
DescriptionReferencesQ & AManualS.D.S


Principle
This kit can detect glucose found within cell culture medium or intracellular glucose by measuring the absorbance of the colored WST formazan dye. The degree of absorbance depends on the amount of glucose present within the sample.This kit contains a glucose standard solution that can be used to create a standard curve. This allows for the quantitation of glucose levels present in the sample.


Procedure
Procedures are so easy that you simply incubate the plate after the addition of culture supernatant or tissue/cell lysates prior to adding a reagent.


Preparation of Standard Curve
Glucose levels in a sample can be measured by a calibration curve established with Glucose Standards included in this kit. If the glucose levels are greater than or equal to 0.5 mmol/L, the sample must be diluted before measurement.


Measurement of Glucose level in combination with Lactate Assay Kit
By using Glucose Assay Kit-WST and Lactate Assay Kit-WST, we have successfully measured metabolic activity changes of phloretin, a protein transport inhibitor, when it is added to Jurkat cells.


Precautions when using this kit.

Cell counts may need to be normalized. When cells are analyzed in a microplate, the results obtained may sometimes differ depending on cell numbers per well.In such cases, normalization of the measured values obtained from cell counting and total protein will be necessary.In this kit, cell numbers can be easily measured by the fluorescence intensity induced by a reagent added to cell culture medium for staining nuclei.

No.SampleReference
1)Serum
(Mouse)
M. Shinohara, Y. Tashiro, M. Shinohara, J. Hirokawa, K. Suzuki, M. O. Takeya, M. Mukouzono, S. Takeda, T. Saito, A. Fukumori, T. C. Saido, R. Morishita and N. Sato, “Increased levels of Aβ42 decrease the lifespan of ob/ob mice with dysregulation of microglia and astrocytes”, FASEB J., 2019,DOI: 10.1096/fj.201901028RR
2)Microorganism
(Streptomyces albulus )
K. Yamanaka, Y. Hamano and T. Oikawa, “Enhancement of metabolic flux toward ε-poly-l-lysine biosynthesis by targeted inactivation of concomitant polyene macrolide biosynthesis in Streptomyces albulus.”, J. Biosci. Bioeng., 2020,DOI: 10.1016/j.jbiosc.2019.12.002
3)Cell
(HCT116)
K. Ohshima, S. Nojima, S. Tahara, M. Kurashige, K. Kawasaki, Y. Hori, M. Taniguchi, Y. Umakoshi, D. Okuzaki, N. Wada, J. Ikeda, E. Fukusaki and E. Morii, “Serine racemase enhances growth of colorectal cancer by producing pyruvate from serine”, Nat Metab, 2020, 2(1), 81
4)Cell
(Leukemia P388)
T. Matsuo, Y. Konya, E. Hirayama and Y. Sadzuka , “2-Deoxy-D-glucose enhances the anti-cancer effects of idarubicin on idarubicin-resistant P388 leukemia cells”, Oncol Lett , 2020, 20(1), 962-966
5)Cell
(Mouse : sperm)
M. Hashimoto, S. Kimura, C. Kanno, Y. Yanagawa, T. Watanabe, J. Okabe, E. Takahashi, M. Nagano and H. Kitamura, “Macrophage ubiquitin specific protease 2 contributes to motility, hyperactivation, capacitation, and in vitro fertilization activity of mouse sperm”, Cellular and Molecular Life Sciences, 2020, doi: 10.1007/s00018-020-03683-9

*When measuring samples other than cell culture supernatants, please check the Q&A “Precautions when measuring samples other than cell culture supernatants” in advance.

Precautions when measuring samples other than cell culture supernatants
Samples other than cell culture supernatants, such as cell lysates and plasma, contain proteins and can result in the increased background fluorescence. Therefore, we recommend to remove proteins in the sample. For details, please refer to the Q&A “Can I measure the intracellular glucose?”.
I do not have a 450 nm filter. What other filters can I use?
You can use filters with an absorbance between 450 nm and 490 nm. However, the absorbance value can become lower if the sample is not measured at 450 nm.
Can I quantify L-Glucose levels?
No, the kit is used for the quantification of β-D-Glucose levels.
How many samples can I measure?

* The number of samples that can be recorded when the standard curve and sample is measured in triplicates.

*A plate layout for Glucose standard solution and sample
Can I measure the intracellular glucose?

(1) Collect cells*1 into 1.5 ml microtube.
*The number of cells required for measurement depends on the cell type.
The figures below show the results of the measurement in HepG2 cells and Jurkat cells.
(2) Centrifuge at 300 x g for 5 minutes and remove the supernatant.
(3) Add 300 µl of cold PBS, suspend by pipetting, centrifuge at 300 x g for 5 minutes, and remove the supernatant.
(4) Add 250 µl of Cell Lysis Solution*2 (0.1% Triton-X) and lyse the cells by pipetting.
Centrifuge the cells at 12,000 x g for 5 minutes.
(5) Transfer 200 µl of the supernatant from step (4) to a 10K ultra centrifugal filter and centrifuge at 12,000 x g for 10 minutes.
*If you measure with n=3, in total 150 µl or more sample is required (50 µl per well × 3 wells).
*If the filtrate is not left more than 150 µl after centrifugation, centrifuge it longer.
(6) Use the filtrate obtained in step (5) as a measurement sample.
Then, measure the glucose concentration according to the product manual supplied with the kit.
*If necessary, dilute the test sample with cell lysate to keep it within the calibration curve range (0-0.5 mmol/l).

*1) In order to detect glucose levels of more than 0.02 mmol/l, you need at least 1 x 105 cells HepG2 cells or 2 x 106 Jurket cells.
*2) You cannot use buffers containing SDS because SDS in the cell lysate inhibits coloring of the dye in the kit.

Related Categories
Cell Proliferation / Cytotoxicity Intracellular Fluorescent Probes Cellular Metabolism

Related Products

COVID-19 Announcement

Due to rising concerns regarding the COVID-19 (Coronavirus 2019) outbreak, Dojindo Molecular Technologies, Inc will be taking the necessary steps to prioritize public health and safety.

Scroll to Top